Construction and Civil
The lunch and smoko room from site establishment to handover, set up beside the site office and ablutions.
The range
Fitted 20ft lunch rooms with a plumbed kitchenette, delivered ready to connect
SCS Australia builds portable lunch rooms on a new 20ft high cube: the same lined, wired and cooled shell as our site offices, with a plumbed kitchenette added and the split system mounted high on the end wall. Each one seats up to nine people. We supply them to construction, mining and remote sites and deliver Australia-wide. The lunch room belongs to our portable buildings range, and every unit is quoted as a delivered build.
The range
The range opens with one lunch room container, the 20ft lunch room, with about 12 m² of floor and seating for nine. Larger crews start from the 40ft site office with a lunch room, which is partitioned as an office and a crib room, or as two crib rooms so breaks can run in shifts.
Portable Lunch Rooms
A crib room is the site lunch room: the mining and WA name for the building where a crew eats, takes drinks and shelters on breaks. Construction sites call the same building a lunch room or smoko room.
Sites need one because of a legal duty. Under the model WHS Regulations, the person conducting a business or undertaking (PCBU) must give workers somewhere to eat, with drinking water and hand washing close by. Safe Work Australia’s Code of Practice: Managing the work environment and facilities explains how a workplace meets that duty, and on a greenfield site or a remote pad a fitted lunch room meets it from the first day on site. Food safety law is a separate question. A crew lunch room used for reheating meals and making drinks is not a food business, so Chapter 3 of the FSANZ Food Standards Code does not apply unless food is prepared there for sale.
Portable Lunch Rooms
Every lunch room arrives with a plumbed kitchenette, a reverse-cycle split system mounted high on the end wall, insulated panels and a full electrical fit-out. It is the 20ft site office turned into a kitchenette container: a sink with hot and cold water, a stainless steel benchtop, and space and power for a microwave and fridge, which are provided for but not supplied. The Midea unit leaves the wall below clear for benches and the kitchenette, and its outdoor unit is set into the wall inside the 20ft footprint. Walls and ceiling are 50 mm rock wool panels faced in RAL 9010 white, and the 20 mm cement fibre floor is finished in coved 2 mm vinyl. A 15-way switchboard with RCD safety switches and 40 kA surge protection is wired to AS/NZS 3000, with switchable LED downlights and GPOs. A hard-wired smoke alarm, a fire-rated steel door with lockbox and double-glazed, flyscreened sliding windows with security bars or shutters complete it.
Sizes and specs
The 20ft lunch room is 6,058 × 2,438 × 2,896 mm outside, about 12 m² inside, and seats up to nine. Inside, the lined room measures 5,770 × 2,150 × 2,440 mm. Entry-level builds sit on a 2,591 mm general purpose shell instead of the high cube, and both keep the ISO 668 20ft footprint. The plate carries a 10,000 kg maximum gross weight. Tare is typically 2,500 kg, which is the site office’s 2,300 kg plus about 200 kg for the kitchenette, sink and hot water, leaving a typical payload of 7,500 kg. Each weight is confirmed for your build when we quote. Seating for nine assumes tables and benches, which we arrange at order rather than fit as standard. The full specification is on the 20ft lunch room container page.
| 20ft Lunch Room | |
|---|---|
| Outside, high cube (L × W × H) | 6,058 × 2,438 × 2,896 mm |
| Outside, general purpose (entry level) | 6,058 × 2,438 × 2,591 mm |
| Inside (typical, as lined) | 5,770 × 2,150 × 2,440 mm |
| Floor area | About 12 m² |
| Seating | Up to 9 people |
| Tare weight | 2,500 kg (typical) |
| Maximum gross weight, plated | 10,000 kg |
| Payload | 7,500 kg (typical) |
Specifications conform to industry standards. Confirm to project requirements.
Applications
Construction, mining, energy, farm and event sites all use the same portable crib rooms, with mine-spec electrics where the site requires them. Because each unit is a steel container shell, container crib rooms move between jobs as a standard lift, and a single unit can work as a mobile crib room that follows the work front along a road or pipeline job.
The lunch and smoko room from site establishment to handover, set up beside the site office and ablutions.
Portable crib rooms for pit, plant and maintenance crews. The mine-spec version adds smoke alarms, exit lighting and illuminated signs, with engineering documents for site audits.
A crew room at plants and remote pads, with AS/NZS 1170 Region D tie-down engineering for the Pilbara and North Queensland.
A break room for harvest and shed crews, delivered to the yard or paddock by tilt tray.
A staff break room behind festivals, shows and sporting events, lifted out once the event packs down.
Portable Lunch Rooms
The shell follows ISO 668 and carries a CSC plate. The fit-out follows the NCC, AS/NZS 3000 and AS/NZS 3500. The CSC safety plate covers the unit in transport and is confirmed for each build at quote. Fit-out materials satisfy the current edition of the National Construction Code wherever a site classes the lunch room as a building. AS/NZS 3000 covers the wiring, switchboard, RCDs, lighting and the kitchenette GPOs. AS/NZS 3500 covers the plumbing and drainage for the sink and hot water, and it applies to every lunch room because the kitchenette is standard. On a site office it applies only when plumbing is added. The double-glazed windows are made to the AS/NZS glazing standard. Units bound for Region D cyclonic areas come with AS/NZS 1170 wind-load engineering and tie-down documentation. Mine-spec builds add smoke alarms, exit lighting and illuminated signs, with engineering documentation for the site’s audit.
Delivery
Builds typically take 4 to 6 weeks once the design is final and the quote is accepted, and delivery and installation generally take 1 to 2 days. Each portable lunch room for sale in the range ships with its fit-out complete: the kitchenette is plumbed in the factory, the panels lined and the circuits wired before dispatch. On site the work is connection. The unit needs a level pad, a power supply, a standard hose connection to its water inlet and somewhere for the grey water outlet to drain. Because the split system’s outdoor unit is set into the wall, nothing projects past the 20ft footprint. That keeps transport routine: the unit goes in by tilt tray, side-loader or crane like any other 20ft container, never as an oversize load, and it moves to the next job the same way. Site access, crane hire and unloading are covered on our delivery options page.
Customisation
Options are fitted in the factory before dispatch, so the lunch room lands finished. Tables and benches are not standard and are arranged at order to suit the crew.
Payments can be spread through our finance options.
Related ranges
A lunch room usually sits in a compound with an office, amenities and a workshop. Crews that need toilets beside the lunch room add portable bathrooms and toilets.
FAQ
None in the building itself. Crib room is the mining and Western Australian term, and construction sites say lunch room or smoko room. SCS builds one unit for both, the 20ft lunch room.
Up to nine, across about 12 m² of floor. Tables and benches are not standard, so we arrange them at order to suit the crew and the space around the kitchenette.
The kitchenette has the space and the power points for a microwave and a fridge, plus a sink with hot and cold water and a stainless steel benchtop. The appliances themselves are not supplied.
A level pad, a power supply, a standard hose connection for water and somewhere for the grey water outlet to drain. The kitchenette is plumbed to AS/NZS 3500 before dispatch.
Builds typically take 4 to 6 weeks once the design is final and the quote is accepted. Delivery and installation generally take 1 to 2 days.
A 12-month limited warranty from delivery covers the building, on top of your rights under Australian Consumer Law, and component manufacturer warranties, such as on electrical parts, pass to you. It excludes misuse, unauthorised modifications and minor transport marks.
We quote the delivered cost of your exact build. Price depends on the shell, the fit-out level, options such as tables or mine-spec electrics, and the distance to your site.
Worksite range
Site offices, ablution blocks, lunch rooms and workshops: the container buildings that keep a site running, delivered together or one at a time.
Site office containers & shipping container offices for sale in 10ft, 20ft & 40ft. Insulated, air conditioned,…
View range
Buy ablution block containers in Australia. Portable bathroom, toilet & shower container units. Durable, hygienic &…
View rangeOur portable lunch rooms for sale are quoted as delivered builds. Send us your crew size, the layout you want and the delivery address, and SCS sends back a priced build with drawings.